자료유형
발행기관
- 한국탄소학회(12)
- 한국지구물리물리탐사학회(6)
- 한국통계학회(6)
- 대한전자공학회(5)
- 한국비파괴검사학회(5)
- 한국음향학회(4)
- 대한화학회(3)
- 한국지구물리탐사학회(3)
- 대한기계학회(2)
- 대한방사선종양학회(2)
- 대한의용생체공학회(2)
- 생화학분자생물학회(2)
- 테크노프레스(2)
- 한국의학물리학회(2)
- 대한방사선과학회(1)
- 대한방사선사협회(1)
- 대한수의학회(1)
- 대한원격탐사학회(1)
- 대한전기학회(1)
- 대한핵의학회(1)
- 대한환경공학회(1)
- 제어로봇시스템학회(1)
- 한국광학회(1)
- 한국데이터정보과학회(1)
- 한국멀티미디어학회(1)
- 한국목재공학회(1)
- 한국방송공학회(1)
- 한국식물병리학회(1)
- 한국안광학회(1)
- 한국자기공명학회(1)
- 한국전산응용수학회(1)
- 한국전자통신학회(1)
- 한국정밀공학회(1)
- 한국정보과학회(1)
- 한국정보교육학회(1)
- 한국정보처리학회(1)
- 한국지반공학회(1)
- 한국지진공학회(1)
- 한국지하수토양환경학회(1)
- 한국통신학회(1)
- 한국해양정보통신학회(1)
간행물
- CARBON LETTERS(12)
- 지구물리와 물리탐사(6)
- 비파괴검사학회지(5)
- THE JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA(4)
- 한국통계학회 논문집(4)
- 물리탐사(3)
- BULLETIN OF THE KOREAN CHEMICAL SOCIETY(2)
- JOURNAL OF THE KOREAN STATISTICAL SOCIETY(2)
- STRUCTURAL ENGINEERING AND MECHANICS : AN INTERNATIONAL JOURNAL(2)
- 의공학회지(2)
- 의학물리(2)
- 전자공학회논문지. JOURNAL OF THE INSTITUTE OF ELECTRONICS ENGINEERS OF KOREA. SP, 신호처리(2)
- BMB REPORTS(1)
- INTERNATIONAL JOURNAL OF CONTROL, AUTOMATION AND SYSTEMS(1)
- JOURNAL OF APPLIED MATHEMATICS & COMPUTING(1)
- JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY(1)
- JOURNAL OF SEMICONDUCTOR TECHNOLOGY AND SCIENCE(1)
- JOURNAL OF THE INSTITUTE OF ELECTRONICS ENGINEERS OF KOREA(1)
- JOURNAL OF THE KOREAN MAGNETIC RESONANCE SOCIETY(1)
- JOURNAL OF VETERINARY SCIENCE(1)
- THE PLANT PATHOLOGY JOURNAL (1)
- 대한기계학회논문집(1)
- 대한방사선기술학회지(1)
- 대한방사선종양학회지(1)
- 대한방사선협회지(1)
- 대한원격탐사학회지(1)
- 대한치료방사선과학회지(1)
- 대한핵의학회지(1)
- 대한화학회지(1)
- 대한환경공학회지(1)
- 멀티미디어학회논문지(1)
- 목재공학(1)
- 방송공학회논문지(1)
- 전기학회논문지= THE TRANSACTIONS OF THE KOREAN INSTITUTE OF ELECTRICAL ENGINEERS(1)
- 전자공학회논문지. JOURNAL OF THE INSTITUTE OF ELECTRONICS ENGINEERS OF KOREA. TC, 통신(1)
- 정보과학회논문지. JOURNAL OF KIISE. 소프트웨어 및 응용(1)
- 정보교육학회논문지(1)
- 정보처리학회논문지. KIPS TRANSACTIONS ON SOFTWARE AND DATA ENGINEERING. 소프트웨어 및 데이터 공학(1)
- 지하수토양환경(1)
- 한국광학회지(1)
- 한국데이터정보과학회지(1)
- 한국생화학회지(1)
- 한국안광학회지(1)
- 한국전자통신학회 논문지(1)
- 한국정밀공학회지(1)
- 한국지반공학회논문집(1)
- 한국지진공학회논문집(1)
- 한국통신학회논문지. THE JOURNAL OF KOREA INFORMATION AND COMMUNICATIONS SOCIETY. 무선통신(1)
- 한국해양정보통신학회논문지(1)
-
Homomorphic Deconvolution 법에 의한 초음파 감쇄정수 추정
홍승홍, 허웅 대한의용생체공학회 의공학회지 8 Pages
대한의용생체공학회 의공학회지 1984, Vol.5 No.1 39-46 (8 pages)
-
급성 뇌경색 환자에서 Deconvolution perfusion CT의 유용성 : Diffusion MRI와 비교
은성종, 김영근, Eun. Sung-Jong, Kim. Young-Keun 대한방사선과학회 대한방사선기술학회지 7 Pages
대한방사선과학회 대한방사선기술학회지 2003, Vol.26 No.3 25-31 (7 pages)
급성 허혈성 뇌경색 환자에서 Deconvolution 관류 전산화 단층촬영(computed tomography, CT)의 뇌혈류용적(cerebral blood volume, CBV), 뇌혈류(cerebral blood flow, CBF) 그리고 평균 조영제 통과 시간(mean transit time, MTT) 지도를 확산 강조(Diffusion weighted) MRI과 비교하여 그 유용성을 알아보고자 하였다. 뇌관류 CT와 확산강조 자기공명영상(diffusion weighted MR imaging, DWMRI)을 시행한 급성뇌경색 환자를 대상으로 Deconvolution 기법으로 획득한 CBV, CBF, MTT 지도에서 병변의 면적과 DWMRI의 병변의 면적을 비교... -
Effect of chronic lead intoxication on the distribution and elimination of amoxicillin in goats
Ahmed M. Soliman, Ehab A. Abu-Basha, Salah A. H. Youssef, Aziza M. Amer, Patricia A. Murphy, Catherine C. Hauck, Ronette Gehring 대한수의학회 Journal of Veterinary Science 9 Pages
대한수의학회 Journal of Veterinary Science 2013, 제 14권 제 4호 4 395-403 (9 pages)
A study of amoxicillin pharmacokinetics was conducted in healthy goats and goats with chronic lead intoxication. The intoxicated goats had increased serum concentrations of liver enzymes (alanine aminotransferase and γ-glutamyl transferase), blood urea nitrogen, and reactivated δ-aminolevulinic acid dehydratase compared to the controls. Following intravenous amoxicillin (10 mg/kg bw) in control and lead-intoxicated goats, elimination half-lives were 4.14 and 1.26 h, respectively. The volumes... -
Profiling of Disease-Related Metabolites in Grapevine Internode Tissues Infected with Agrobacterium vitis
한국식물병리학회 The Plant Pathology Journal 11 Pages
한국식물병리학회 The Plant Pathology Journal 2016, 32권 6호 1 489-499 (11 pages)
Green shoot cuttings of 10 different grapevine species were inoculated with Agrobacterium vitis to find disease-related metabolites in the grapevine. Crown galls formed 60 days after inoculation varied in gall severity (GS) evaluated by gall incidence (GI) and gall diameter (GD), which were classified into three response types as RR (low GI and small GD), SR (high GI and small GD), and SS (high GI and large GD), corresponding to resistant, moderately resistant, and susceptible responses,... -
Graphitization of PAN-based carbon fibers by CO₂ laser irradiation
Liangbo Yao, Weimin Yang, Sanyang Li, Yang Sha, Jing Tan, Ying An, Haoyi Li 한국탄소학회 Carbon Letters 6 Pages
한국탄소학회 Carbon Letters 2017, Vol.24 13 97-102 (6 pages)
Graphite fibers are materials with a high specific modulus that have attracted much interest in the aerospace industry, but their high manufacturing cost and low yield are still problems that prevent their wide applications in practice. This paper presents a laser-based process for graphitization of carbon fiber (CF) and explores the effect of laser radiation on the microstructure of CF. The obtained Raman spectra indicate that the outer surface of CF evolves from turbostratic structures into a... -
Interconnected meso/microporous carbon derived from pumpkin seeds as an efficient electrode material for supercapacitors
Mayakrishnan Gopiraman, Somasundaram Saravanamoorthy, Seung-Hyun Kim, Ill-Min Chung 한국탄소학회 Carbon Letters 9 Pages
한국탄소학회 Carbon Letters 2017, Vol.24 10 73-81 (9 pages)
Interconnected meso/microporous activated carbons were prepared from pumpkin seeds using a simple chemical activation method. The porous carbon materials were prepared at different temperatures (PS-600, PS-700, PS-800, and PS-900) and demonstrated huge surface areas (645?2029 m2 g?1) with excellent pore volumes (0.27?1.30 cm3 g?1). The wellcondensed graphitic structure of the prepared activated carbon materials was confirmed by Raman and X-ray diffraction analyses. The presence of heteroatoms (O... -
High-energy-density activated carbon electrode for organic electric-double-layer-capacitor using carbonized petroleum pitch
Poo Reum Choi, Sang-Gil Kim, Ji Chul Jung, Myung-Soo Kim 한국탄소학회 Carbon Letters 11 Pages
한국탄소학회 Carbon Letters 2017, Vol.22 8 70-80 (11 pages)
Activated carbons (ACs) have been used as electrode materials of electric double-layer capacitors (EDLC) due to their high specific surface areas (SSA), stability, and ecological advantages. In order to make high-energy-density ACs for EDLC, petroleum pitch (PP) precarbonized at 500?1000°C in N2 gas for 1 h was used as the electrode material of the EDLC after KOH activation. As the pre-carbonization temperature increased, the SSA, pore volume and gravimetric capacitance tended to decrease, but... -
Effect of carbonization temperature on crystalline structure and properties of isotropic pitch-based carbon fiber
Jung Dam Kim, Jae-Seung Roh, Myung-Soo Kim 한국탄소학회 Carbon Letters 10 Pages
한국탄소학회 Carbon Letters 2017, Vol.21 6 51-60 (10 pages)
Isotropic pitch-based fibers produced from coal tar pitch with the melt-blowing method were carbonized at temperatures ranging from 800 to 1600oC to investigate their crystalline structure and physical properties as a function of the carbonization temperature. The in-plane crystallite size (La) of the carbonized pitch fiber from X-ray diffraction increased monotonously by increasing the carbonization temperature resulting in a gradual increase in the electrical conductivity from 169 to 3800... -
NO gas sensing ability of activated carbon fibers modified by an electron beam for improvement in the surface functional group
Mi-Seon Park, Sangmin Lee, Min-Jung Jung, Hyeong Gi Kim, Young-Seak Lee 한국탄소학회 Carbon Letters 7 Pages
한국탄소학회 Carbon Letters 2016, Vol.20 3 19-25 (7 pages)
Activated carbon fiber (ACF) surfaces are modified using an electron beam under different aqueous solutions to improve the NO gas sensitivity of a gas sensor based on ACFs. The oxygen functional group on the ACF surface is changed, resulting in an increase of the number of non-carbonyl (-C-O-C-) groups from 32.5% for pristine ACFs to 39.53% and 41.75% for ACFs treated with hydrogen peroxide and potassium hydroxide solutions, respectively. We discover that the NO gas sensitivity of the gas sensor...


전체 선택해제

총


