기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
휴반용 분무기의 Nozzle에 관한 연구(I)
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 휴반용 분무기의 Nozzle에 관한 연구(I)
저자명
원장우
간행물명
한국농공학회지
권/호정보
1973년|15권 2호|pp.2980-3001 (22 pages)
발행정보
한국농공학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Nozzle is a part of sprayer and is consists of several elements; swirl plate, vortexchamber, cap and body. The travelling distance of sprayed particles is important in the wide reach nozzle. The factors to influence the travelling distance of the sprayed particles may be the helical angle of swirl plate, the distance of vortex hamber, the slope and the size of cap hole. The study was conducted to examine the effects of these factors on the travelling distance. The results of this study are summarized as follows; 1) There was higher positive correlation(+0.96) between the maximum travelling distance for which amount of sprayed particles was 5cc/cm min. and centro-position of the travelling distance. 2) There was a higher positive correlation(+0.85) between total discharge of sprayed particles and the centro-position of the travelling distance. 3) Main effects and interaction effects of helical angle, pressure, vortex chamber distance and cap slope were significantly affected the travelling distance of sprayed particles. 4) Main effects of helical angle, pressure and cap slope were especially highly significant to influence the travelling disance. 5) Helical angle, pressure, vortex chamber distance and cap slope influenced spraying forward velocity of dise hole, among which cap slope and pressure of nozzle was the most important factors. 6) Effect of change of helical angle on the travelling distance of sprayed particles, was generally a quadratic, the least value of the distance being showed about $45^{circ}$ and the largest at about $15^{circ};and;55^{circ}$, the decreasing rate of the change between $15^{circ};and;25^{circ}$ was very small. 7) Effect of change of pressure on the travelling distance sprayed particles was generally a linear, the increasing rate of the charge was about 1.68, which was the most effective compared to the change of the other factors. 8) Effect of change of vortex chamber distance on the spraying distance was also generally a linear, the increasing rate being about 0.16, which was the least effective. 9) Effect of change of cap slope on the travelling distance was also generally a linear, the increasing rate was about 0.61 and its effect was about medium.