- 복합레진의 중합수축력에 관한 연구
- ㆍ 저자명
- 김부랑,최호영,민병순,박상진,최기운,Kim. Boo-Rang,Choi. Ho-Young,Min. Byung-Soon,Park. Sang-Jin,Choi. Gi-Woon
- ㆍ 간행물명
- 大韓齒科保存學會誌
- ㆍ 권/호정보
- 1992년|17권 2호|pp.331-341 (11 pages)
- ㆍ 발행정보
- 대한치과보존학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The purpose of this study was to measure the polymerization contraction stress of two types of composite resins; chemical cured type(Cliarfil F II, Kuraray, Japan) and photo-cured type(Photo-Clearfil Bright, Kuraray, Japan). The stresses of composite resin by contraction measured with specially designed measuring device(Fig. 1). The stresses caused by shrinkage during hardening of specimens were measured according to the type of composite resins, thickness of specimen(0.65, 1.30 and 1.95mm), and ratio of catalyst to base in case of only chemical cured composite resin(0.5, 1.0 and 1.5). As the composite resin specimen shrank on hardening, the load cell recorded force vs time automatically on pen-recorder(Toa, Japan) with a cross-head speed 60mm/hr at 0~10 voltages up to 2 hours. The experiments were conducted in a room maintained at $23{pm}2^{circ}C$ and relative humidity $50{pm}10%$. The results were as follows. 1. The contraction stress during hardening was higher in photo cured composite resin than in chemical cured composite resin. 2. The contraction stress during hardening was increased with thickness of composite resin specimen. 3. In chemical cured composite resin, the polymerization contraction stress was decreased with ratio of catalyst and base. 4. The contraction stress during polymerization was higher in early time after insertion of photo cured composite resin and chemical cured composite resin.