- 비공비혼합냉매 R-22+R-114를 이용한 열펌프의 성능에 관한 연구
- ㆍ 저자명
- 박기원,구학근,오후규
- ㆍ 간행물명
- 大韓機械學會論文集
- ㆍ 권/호정보
- 1993년|17권 9호|pp.2131-2137 (7 pages)
- ㆍ 발행정보
- 대한기계학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This study, examines the performance and the heat pump cycle systematizing characteristics for non-azeotropic refrigerant systems. In order to conduct such an examination, the cycle characteristics of heat pumps for pure R-22, R-114, and their mixtures were experimentally investigated. The results show that cooling/heating capacities for the mixtures was more suited at the evaporating temperature of $5^{circ}C$ than that of $0^{circ}C$, $-5^{circ}C$, and $-10^{circ}C$. The C.O.P of the 50 wt% mixtures was considerably higher than for pure R-22, and the compression power of the 25 wt% was as much as 60% lower than that of pure R-22. Even small fractional mixture variations can lead to significant changes in the characteristics of the heat pump cycle. This experiment verified the importance of accurate weight fractions of refrigerant mixtures.