- 저자장 영구자석 자기공명영상에서 슬내장 진단의 정확도
- ㆍ 저자명
- 권대익
- ㆍ 간행물명
- 대한방사선의학회지
- ㆍ 권/호정보
- 1995년|32권 5호|pp.807-811 (5 pages)
- ㆍ 발행정보
- 대한영상의학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Purpose: The study is for the evaluation of low tesla(0.064T) MR imaging diagnostic accuracy in the internalderangement of the knee. Materials and Methods: We retrospectively analysed the MR images of 36 njured knees of 35patients. The presence of tear was determined by arthroscopy or surgery in all cases. Results: The sensitivity,specificity, accuracy, positive predictive value, negative predictive value of low tesla MRI for the diagnosis ofanterior cruciate ligament injury were 83%, 88%, 86%, 77%, 91%, for the posterior cruciate ligament 75%, 95%, 86%,92%, 83%, for the medial collateral ligament 83%, 96%, 92%, 91%, 92%, for the lateral collateral ligament 67%,97%, 94%, 67%, 97%, for the menisci 75%, 93%, 89%, 75%, 93%. Conclusion: The low tesla MRI is an accurate methodin detection and evaluation of the internal derangement of the knee.