기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
A SPECTROPHOTOMETRIC STUDY ON DISCOLORATION OF RESTORATIVE COMPOSITE RESINS IN COFFEE AND ARTIFICIAL SALIVA
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • A SPECTROPHOTOMETRIC STUDY ON DISCOLORATION OF RESTORATIVE COMPOSITE RESINS IN COFFEE AND ARTIFICIAL SALIVA
  • A SPECTROPHOTOMETRIC STUDY ON DISCOLORATION OF RESTORATIVE COMPOSITE RESINS IN COFFEE AND ARTIFICIAL SALIVA
저자명
엄승희,조효선,이정식,Eom. Seung-Hee,Cho. Hyo-Sun,Lee. Chung-Sik
간행물명
大韓齒科保存學會誌
권/호정보
1996년|21권 2호|pp.530-545 (16 pages)
발행정보
대한치과보존학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

The purpose of this study was to investigate by spectrophotometry the changes in color parameters of composite resins after exposure to distilled water, filtered coffee, and artificial saliva. Five kinds of fine particle composite resin in experiment 1, and six kinds of composite resin in experiment 2 were used. In experiment 1, each group of composite resin was stored in distilled water at $4^{circ}C$, $50^{circ}C$, and filtered coffee solution at $4^{circ}C$, $50^{circ}C$. And then each specimen was measured by spectrophotometer. Measurements were repeated in 1 hour, 2 hours, 4 hours, 8 hours, 16 hours, 24 hours, and 48 hours. In experiment 2, all specimens of each brand were stored in distilled water at $37^{circ}C$, artificial saliva not contained mucin at $37^{circ}C$, and artificial saliva contained mucin at $37^{circ}C$. All specimens of each brand were measured by spectrophotormeter in 1 week, 2 weeks, 4 weeks, 8 weeks, and up to 12 weeks. The results were as follows : 1. In cold coffee, five of fine particle composite resins showed ${Delta}E{^*}_{ab}$ values less than 2. However, in hot coffee ${Delta}E{^*}_{ab}$ values of Amelogen Universal and Prisma TPH were higher than those of Conquest Crystal, ${AE}$litefil and Z100. 2. Z100 and ${AE}$litefil had better cleansibility of extrinsic coffee staining than Amelogen Universal, Conquest Crystal and Prisma TPH. 3. In distilled water and artificial saliva not contained mucin, five of fine particle composite resin showed ${Delta}E{^*}_{ab}$ values less than 2 up to 12 weeks. However, Silux Plus showed higher than ${Delta}E{^*}_{ab}$ values of fine particle composite resin. 4. As an immersion solution for discoloration experiment, artificial saliva not contained mucin showed similar appearance as distilled water. However, artificial saliva contained mucin had different appearance from the others. 5. In artificial saliva contained mucin, ${AE}$litefil, Prisma TPH and Z100 showed ${Delta}E{^*}_{ab}$ values less than 1 up to 12 weeks. However, Silux Plus, Amelogen Universal and Conquest Crystal showed ${Delta}E{^*}_{ab}$ values more than 1 up to 12 weeks. But, Conquest Crystal showed different characteristics of chromacity difference value(less chromatic) and lightness difference value(lighter) from Silux Plus and Amelogen Universal.