- 석유 홴 히터의 난방 능력 고찰
- ㆍ 저자명
- 김장권,정규조,Kim. Jang-Kweon,Jeong. Kyu-Jo
- ㆍ 간행물명
- 한국동력기계공학회지
- ㆍ 권/호정보
- 1997년|1권 1호|pp.51-60 (10 pages)
- ㆍ 발행정보
- 한국동력기계공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
In this paper, we investigated the heating performance and the basic characteristics required for normal combustion of kerosene fan heater. And also the iso-velocity contours and the iso-temperature contours of hot gas discharged from the exit of kerosene fan heater were analyzed. The experiment was carried out with kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of $240mm{ imes}240mm{ imes}1200mm$. The purpose of this paper was to obtain the basic data for new design from conventional kerosene fan heater. Consequently it was found that (i) the pressure ratio $P_2/P_1$ had a comparatively constant value of 0.844 according to the increase of the revolution of turbo fan, (ii) the primary excess air ratio had a range of $0.84{sim}1.11$ during normal combustion, and (iii) the heating performance of kerosene fan heater had a range of $1,494{sim}3,852kcal/hr$.