- 자동생검출을 이용한 초음파 유도하의 신생검:유용성과 합병증에 관하여
- ㆍ 저자명
- 최필엽
- ㆍ 간행물명
- 대한방사선의학회지
- ㆍ 권/호정보
- 1998년|38권 1호|pp.137-140 (4 pages)
- ㆍ 발행정보
- 대한영상의학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Purpose: To evaluate the diagnostic yield and complications of percutaneous ultrasound-guided renal biopsyusing a biopsy gun in patients with diffuse renal disease. Materials and Methods: Using an automated biopsy gunmounted with a 16G needle, biopsies were performed on 90 patients with diffuse renal disease. In a total of 95biopsies, diagnostic yield, the mean number of glomeruli and frequency of complication were retrospectivelyanalysed. Results: Tissue adequate for histological diagnosis was obtained in 92% of procedures. Mean glomerularyield was 8.3, and complications were seen in 26% of the procedures, 25% of these were minor, and 1% were major.Conclusion: For the diagnosis of diffuse renal disease, utrasound-guided percutaneous renal biopsy using anautomated biopsy gun is accurate and safe.