- 분리형 인버터 에어컨의 운전조건에 따른 성능 연구
- ㆍ 저자명
- 김만회,Kim. Man-Hoe
- ㆍ 간행물명
- 大韓機械學會論文集. Transactions of the Korean society of mechanical engineers. B. B
- ㆍ 권/호정보
- 1998년|22권 1호|pp.113-121 (9 pages)
- ㆍ 발행정보
- 대한기계학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The performance evaluation of a residential split system inverter air-conditioner has been conducted analytically and experimentally at different system operating conditions. A simulation program for modelling an air-conditioning system which consists of a compressor, a condenser, a capillary tube, an evaporator and related attachments was developed on the basis of the Oak Ridge heat pump design model, MARK III. The accuracy of the simulation results for the compressor frequencies of 32, 68 and 79 Hz for the residential split system inverter air-conditioner has been estimated by comparing calculation results to the experimental data and parametric study has been performed to investigate the effect of design parameters and operation conditions on the system performance.