기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
청색증형 선천성 심질환아의 고식적 수술 이후 EBT에 의한 폐혈관계이 비침습적 추적 검사
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 청색증형 선천성 심질환아의 고식적 수술 이후 EBT에 의한 폐혈관계이 비침습적 추적 검사
저자명
김민정,박영환,홍유선,이종균,최규옥,조범구
간행물명
大韓胸部外科學會誌
권/호정보
2000년|33권 1호|pp.7-19 (13 pages)
발행정보
대한흉부외과학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Background :To assess the accuracy of Electron-Beam Tomography(EBT) in following evaluation of the pulmonary vascular system after a shunt operation in the cyanotic con-genital heart disease with pulmonary stenosis or pulmonary atresia. Material and Method : Sixteen patients(M:F=11:5) who received Blalock-Taussig(n=8) bidirectional cavo-pulmonary shunt(n=10) and unifocalization (n=2) were ncluded in the study. We evaluated the patency of the shunt the morphology of intrapericardial and hilar pulmonary arteries(PA) peripheral pulmonary vascularity by background lung attenuation and the abundance of arterial & venous collateral. Angiography(n=12) and echocardiography(n=20) were used as the gold standard for the comparison of EBT results. Result: EBT was consistent with angiogram/ echo in 100% of the evaluation for the patency of the shunt and in 12(by angiogram 100%) and 19(by echo 95%) for the detection the hypoplasia stenosis or interruption of central PA In measuring of PA EBT and angiogram corrlated(r=0.91) better than EBT-echo(r=0.88) or echo-angiogram(r=0.72) Abundant systemic arterial collateral were noted in 4 and venous collateral in 3 cases. In evaluating the peripheral pulmonary vascularity the homogenous and normal-ranged lung attenuation(m=6) decreased but homo-genous attenuation(n=1) segment-by-sgment heterogeneous attenuation(n=3) homogenous but asymmetrical attenuation(n=3) segment-by-segment heterogeneous attenuation(n=3) homogenous but asymmetrical attenuation(n=3) and venous congestion(n=2) were observed nd 12 of them were compatible with the blood flow pattern revealed by cardiac catheterization. Conclusion: EBT was accurate in the integrated evaluation of the pulmonary vascular system after the shunt including the patency of the shunt operaion the morphology and dimension of the central and hilar PAs and the loco-regional pulmonary flow in the lung parenchyma. It suggests the useful information about the need of secondary shunt operation the proper timing time for total repair and the need of interventional procedure prior to total repair