- 고체유전체에서 발생한 부시형 전기트리에 수반된 내부 부분방전 펄스 해석
- Internal PD Pulses Analysis Accompanying with Bush-type Tree in Solid Dielectrics
- ㆍ 저자명
- 강성화,홍현문,류부형
- ㆍ 간행물명
- 한국산업안전학회지
- ㆍ 권/호정보
- 2000년|15권 1호|pp.100-105 (6 pages)
- ㆍ 발행정보
- 한국안전학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Correlation between propagation of bush-type electrical tree and internal partial discharges(PD) was discussed. We used specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope interfaced with computer and investigated characteristics of phase resolved PD pulses accompanying with propagation of electrical tree. Electrical tree generally growed bush-type tree. PD data detected and analyzed were average discharge current and statistical operator of q-n, $psi$- $q_{avg}$, $psi$-n, ${psi}-q_{max}$ distribution. Parameters used were skewness, kurtosis, average discharge phase, cross-correlation factor, asymmetry and etc. In generally, average discharge current had good linear relationship with propagation of bush type electrical tree on this experiment. Peak discharge magnitude and repetition rate were increased, but they had not good linear relationship.p.