- 화력발전소에서 용융회가 열전달 감소에 미치는 영향에 관한 연구
- ㆍ 저자명
- 강희찬,이규욱,Kang. H.C.,Lee. K.W.
- ㆍ 간행물명
- 한국동력기계공학회지
- ㆍ 권/호정보
- 2000년|4권 1호|pp.13-19 (7 pages)
- ㆍ 발행정보
- 한국동력기계공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This study was conducted for the heat transfer reduction due to the clinker formed in the furnace of the thermal power plant. The thermal properties of clinker such as thermal conductivity, specific heat, density and void fraction were measured. The thermal conductivities of the clinker were ranged $0.32-0.54W/m{cdot}K$ and the average specific heat and the void fraction were $930J/kg{cdot}K$ and 0.36 respectively. The thermal resistance of clinker was the greatest among the thermal resistances. It was found that the clinker reduces more than 90% of the heat transfer if the clinker is thicker than 10 cm.