- 역지밸브 채터링 현상 해소방안 연구
- ㆍ 저자명
- 유기완,이준신,김태룡
- ㆍ 간행물명
- 한국소음진동공학회논문집
- ㆍ 권/호정보
- 2002년|12권 1호|pp.36-41 (6 pages)
- ㆍ 발행정보
- 한국소음진동공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The cause and the elimination method for the chattering phenomena were investigated in a check valve attached to the exit of an auxiliary cooling water pump in a Korean nuclear powerplant. From the site experiment and the numerical calculation, the incident angle of the disk was so small that it was not able to produce the sufficient lifting force to overcome the gravitational component of the disk weight. Moreover, it turned out that the installation position was not symmetric for the secondary vortical flow generated inside the elbow so that the flow structure had strongly unstable flow characteristics. From this study, the tapping noise and the chattering phenomena were eliminated exactly by changing the incidence angle of the valve disk and the installation position of the calve body.