- 냉각탑수의 레지오넬라균과 박테리아균 등 미생물 분포 및 상관성 비교
- ㆍ 저자명
- 방선재,이철민,김윤신,선우영,박용배
- ㆍ 간행물명
- 大韓衛生學會誌
- ㆍ 권/호정보
- 2002년|17권 3호|pp.1-6 (6 pages)
- ㆍ 발행정보
- 대한위생학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This study was carried out to investigate the distribution of Legionella spp and microbe from cooling towers water of Public establishments in Seoul and Gyeonggi-Do. As results of this study, the cooling tower 132 sites were detecting L. pneumophila in order to July(12%) > August (14%) > June, September no-detected. The public establishments were detecting L. pneumophila in order to Department store(27.3%) > Hospital(8.7%) > Office(5.9%) > Big Mart(5.0%) > Hotel, Subway no-detected. The correlation coefficient pH and L.pneumophila showed 0.62(p=0.05), 0.27(p=0.45) in temperature and L.pheumophila, 0.40(p=0.25) in turbidity and L.pneumophila.