- PCS측정 기술과 Kozeny-Carman 모델을 이용한 여과공정 특성연구
- ㆍ 저자명
- 하상안,김승호,윤태경
- ㆍ 간행물명
- 한국환경과학회지
- ㆍ 권/호정보
- 2004년|13권 9호|pp.799-806 (8 pages)
- ㆍ 발행정보
- 한국환경과학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The filtration tests were made in cell with a low concentrated suspension. The suspension with a concentration of $C_{M}$=1.14~2.67$cdot$$10^{-3}$ g/g consists of paper paint and water. The particles in the suspension have a particle size x<1${mu}m$. The used depth filters consists of glass fibres, which are coated by polymer. The filtration in depth filters accorded in different mechanism, which were explained by physical models. The model which would be allows to make a promise of the filtration reaction. This filter media allows to get a high filtration time and a good separation rate. The Particle distribution is measured by a photon correlation spectroscopy(PCS). PCS measures particle sizes 0.03 ${mu}m$<d<3 <${mu}m$ in the suspension. The filtered suspension has a very low concentration Co{le}5{ imes}10_{-4}$ g/g of solid in sample. The PCS also informs us about the number of the particles in the suspension. The makes it possible to calculate the concentration of the in sample.