- 루프 히트파이프의 작동에 영향을 미치는 인자에 대한 이론적 분석
- ㆍ 저자명
- 이기우,전원표,이욱현,박기호,Lee. Ki-Woo,Chun. Won-Pyo,Lee. Wook-Hyun,Park. Ki-Ho
- ㆍ 간행물명
- 설비공학논문집
- ㆍ 권/호정보
- 2004년|16권 12호|pp.1107-1116 (10 pages)
- ㆍ 발행정보
- 대한설비공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
In this paper, the effects of diverse parameters on the operation of loop heat pipe (LHP), such as particle diameter of sintered porous wick, wick porosity, vapor line diameter, thickness of wick and heating capacity were investigated by a theoretical analysis. A LHP has a wick only in its evaporator for the circulation of working fluid, and utilizes a porous wick structure of which pore size is very small to obtain a large capillary force. The working fluid is water and the material of sintered porous wick is copper. For these different parameters, capillary pressure, pressure drop in wick, pressure drops and temperature distribution were analyzed by a theoretical design method of LHP.