- 데오드라이트 시스템의 측정 정확도에 대한 연구(IV) - 시준거리 4m에서의 기준자 거리에 따른 측정 정도
- ㆍ 저자명
- 윤용식,이동주,박요창,Yoon. Yong-Sik,Lee. Dong-Ju,Park. Yo-Chang
- ㆍ 간행물명
- 한국공작기계학회논문집
- ㆍ 권/호정보
- 2005년|14권 3호|pp.67-73 (7 pages)
- ㆍ 발행정보
- 한국공작기계학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
An accuracy of theodolite system may be affected by a measurement environment and a measurement distance change from theodolite to scale bar and/or targets. This study was performed for measuring an accuracy when the distance from thodolite system to scale bar was changed $2~6m$ on the distance 4m between two theodolites. The results showed that an accuracy was ${pm}0.025mm$ or better when the distance from theodolite system to targets was 3, 4 and 5m. According to the results, it was found that the best distance from theodolite system to scale bar was $3~4m$ when the collimation distance was $3~4m$.