- 옥내 전력선 통신 채널 임피던스 측정 장치 설계
- ㆍ 저자명
- 허윤석,Heo. Yun-Seok
- ㆍ 간행물명
- 情報學硏究
- ㆍ 권/호정보
- 2005년|8권 3호|pp.25-33 (9 pages)
- ㆍ 발행정보
- 한국정보기술전략혁신학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency 30khz$sim$1Mhz band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.