기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
상악 임플랜트 Overdenture에서 Bar Attachment 설계에 따른 유지력 변화에 관한 연구
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 상악 임플랜트 Overdenture에서 Bar Attachment 설계에 따른 유지력 변화에 관한 연구
  • COMPARATIVE STUDIES OF RETENTIVE FORCES IN MAXILLARY OVERDENTURE BAR ATTACHMENTS
저자명
손차영,정창모,전영찬,임장섭,정희찬,Son. Cha-Young,Jeong. Chang-Mo,Jeon. Young-Chan,Lim. Jang-Seop,Jeong. Hee-Chan
간행물명
대한치과보철학회지
권/호정보
2005년|43권 5호|pp.650-661 (12 pages)
발행정보
대한치과보철학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Statement of problem: It could be hypothesised that attachments, which provide more retention against vortical and horizontal dislodgement, will be associated with more favorable parameters of oral function. Purpose: This study was to provide data of initial retentive force and retention loss of different bar attachment systems recommended for use with maxillary implant overdentures. Material and method: 4 implants were placed in the anterior region of edentulous maxilla, five different systems of bar attachment were fabricated as follows: cantilevered Hader bar using clips (Type 1), Hader bar using clips without cantilever (Type 2), Hader bar using clip and ERA attachment orange male (Type 3), Hader bar using clip and ERA attachment white male (Type 4), and Bar using magnets (Type 5). Each samples were placed in the universal testing machine for determination of retentive forces(at initial and after every 200 cycles up to 1,000 cycles). Results and Conclusion 1. Attachment type 1 showed the biggest initial retentive force followed by type 3, type 2, type 4, and lastly type 5(P<0.001). 2. After 1,000 cycles of repeated removals of attachments, significant loss of retentive forces was taken place except for attachment type 5. 3. After 1,000 cycles of repeated removals, the loss of retentive force between type 1 and type 2, which used Hader bar and clip attachments. was greater in type 1 that had wider clip formation. And between type 3 and type 4, which used ERA attachments, the loss of retentive force was greater in type 4 that had white male attached (P<0.001). 4. After 1.000 cycles of repeated removals, attachment type 3 showed the biggest retentive force followed by type 2, type 4, type 1 and lastly type. 5. There was no significant difference between attachment type 3 and 4, and type 4 and 1(P<0.001).