기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
모아레를 이용한 체형분석의 반복성 재현성에 관한 연구
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 모아레를 이용한 체형분석의 반복성 재현성에 관한 연구
  • Study on the Repeatability and Reproductivity of a Moire Body Shape Analyser
저자명
이동엽,박영배,오환섭,Lee. Dong-Yup,Park. Young-Bae,Oh. Hwan-Sub
간행물명
大韓漢醫診斷學會誌= The journal of the Korea institute of oriental medical diagnostics
권/호정보
2006년|10권 2호|pp.121-131 (11 pages)
발행정보
대한한의진단학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Background : As each human has a look in the face of oneself, he or she has a look of him or herself in the shape of the body also. And for the shape of the body which gives a big clue in diagnosis in musculoskeletal disorders. Therefor many means are used and developed for diagnosis through body shape or posture analysis for musculoskeletal disorders. X-ray, CT, MRI has been used for diagnosis through image in this way to tell about the inside of the human body. On the other side, moire topography was used for information about the exterior of the human body, but yet only minimal information such as the number of contour lines in each side was available. Therefor there were a few studies to use moire topography or other methods to get information about the surface of the human body in numeric values. The instrument used in this study which is a laser projection moire, is another trial to get numeric data about the surface of the human body. The instrument is composed of laser projector and a computer software to recompose and analyse the image data into depth, height, angle and length. Objectives : The study was focused on whether the instrument is reliable for clinic use, and to seek the proper environment and posture for the examination, and among the data the software provides, which items are more reliable and useful. Methods : For reproductivity and repeatability, 4 testers tested 2 persons. And to how if the body shape changes according to the posture and which posture gives the most reliable data, the test was performed in 6 different positions. Results : Result, the instrument showed sufficient repeatability and reproductivity for clinical use. And among the items the software provides, the length of the back, the angle of the back in the sagittal and coronal plane showed reliable results. And there was difference in the results according to the posture, and Therefor, in following studies using this instrument or similar type of posture analysing instruments, the length of the back, the angle of the back in the sagittal and coronal plane could be reliable item to use.