- 공압실린더의 누설유량 계측방법에 관한 연구
- ㆍ 저자명
- 장지성,지상원,정지현,강보식,Jang. J.S.,Ji. S.W.,Jeong. J.H.,Kang. B.S.
- ㆍ 간행물명
- 유공압시스템학회논문집
- ㆍ 권/호정보
- 2006년|3권 1호|pp.15-19 (5 pages)
- ㆍ 발행정보
- 유공압시스템학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measure from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing steel wool into it. Therefore, wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.