- 학교교실의 냉방시 실내열.공기환경 실태
- ㆍ 저자명
- 최윤정,정연홍,이선아,김혜경,황진아,Choi. Yoon-Jung,Jeong. Youn-Hong,Lee. Seon-A,Kim. Hye-Kyeong,Hwang. Jin-A
- ㆍ 간행물명
- 한국주거학회 논문집
- ㆍ 권/호정보
- 2007년|18권 4호|pp.49-58 (10 pages)
- ㆍ 발행정보
- 한국주거학회|한국
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The purpose of this study were to make clear the present condition of indoor thermal and air environment by cooling in school classrooms and to analyze the relation of the living conditions with indoor environment. The measurements on physical elements and observations on living conditions were carried out in 6 classrooms of 3 middle or high schools. Measuring elements were indoor temperature, relative humidity, PM10 and $CO_2$ concentration. As results, the averages of indoor temperature each classrooms were $24.9{sim}26.6^{circ}C$. Most of classrooms were lower than the Maintenance standard $(26{sim}28^{circ}C)$ of School Health Law. The means of relative humidity were $51.3{sim}72%$, all classrooms were ranged within the standard $(30{sim}80%)$. The means of PM10 concentration were $3.5{sim}23.1{mu}g/m^3$, all classrooms were kept within the standard $(100{mu}g/m^3)$. The means of $CO_2$ concentration were $1218.7{sim}4705.4ppm$, all classrooms were exceed the standard (1,000ppm). The results of analysis on relations of living conditions with the physical elements are as follow; the air conditioner set of temperature, windows and doors opening elapsed time, the number of students in classrooms and activities of students had certain effect on indoor environment.