기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Characteristics of Expanded Graphite Filled Conductive Polymer Composites for PEM Fuel Cell Bipolar Plates
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Characteristics of Expanded Graphite Filled Conductive Polymer Composites for PEM Fuel Cell Bipolar Plates
  • Characteristics of Expanded Graphite Filled Conductive Polymer Composites for PEM Fuel Cell Bipolar Plates
저자명
Oh. K.S.,Heo. S.I.,Yun. J.C.,Yang. Y.C.,Han. K.S.
간행물명
Advanced composite materials : the official journal of the Japan Society of Composite Materials and the Korea Society for Composite Materials
권/호정보
2008년|17권 3호|pp.259-275 (17 pages)
발행정보
한국복합재료학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

This study aims to optimize the mechanical and electrical properties of electrically conductive polymer composites (CPCs) for use as a material of bipolar plates for PEM fuel cells. The thin CPCs consisting of conductive fillers and polymer resin were fabricated by a preform molding technique. Expanded graphite (EG), flake-type graphite (FG) and carbon fiber (CF) were used as conductive fillers. This study tested two types of CPCs, EG/FG filled CPCs and EG/CF filled CPCs, to optimize the material properties. First, the characteristics of EG/FG filled CPCs were investigated according to the FG ratio for 7 and $100{mu}m$ sized FG. CPCs using $100{mu}m$ FG showed optimal material properties at 60 wt% FG ratio, which were an electrical conductivity of 390 S/cm and flexural strength of 51 MPa. The particle size was an important parameter to change the mechanical and electrical behaviors. The flexural strength was sensitive to the particle size due to the different levels of densification. The electrical conductivity also showed size-dependent behavior because of the different contributions to the conductive network. Meanwhile, the material properties of EG/CF filled CPCs was also optimized according to the CF ratio, and the optimized electrical conductivity and flexural strength were 290 S/cm and 58 MPa, respectively. The electrical conductivity of this case decreased similarly to the EG/FG filled case. On the other hand, the behavior of the flexural strength was more complicated than the EG/FG filled case, and the reason was attributed to the interaction between the strengthening effect of CF and the deterioration of voids.