- 인듀서와 임펠러 축방향 간극이 터보펌프 성능에 미치는 영향
- ㆍ 저자명
- 최창호,김대진,홍순삼,김진한,Choi. Chang-Ho,Kim. Dae-Jin,Hong. Soon-Sam,Kim. Jin-Han
- ㆍ 간행물명
- 유체기계저널
- ㆍ 권/호정보
- 2008년|11권 5호|pp.37-43 (7 pages)
- ㆍ 발행정보
- 유체기계공업학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
An inducer is employed in a modern rocket feed system because it allows a turbopump system to operate at a high speed with low inlet pressures so as to minimize the weight and the size of the system. Cavitation performance can be improved by installing an inducer to the pump, enabling to increase the operational speed of the pump. The main purpose of an inducer is to increase the static pressure prior to an impeller to enable the impeller to operate satisfactorily under cavitation environments. In the present study the effects of axial distance between the inducer and the impeller on the performance of the pump were studied using both experimental and computational methods. Two inducers with different axial length were used for the experiments and the pump performances were measured. The experimental results show that the suction performance decreases as the axial gap between the inducer and impeller is increased.