- 안와 경사의 분석을 위한 정모 두부규격방사선사진, 3D-CT의 유용성 평가
- ㆍ 저자명
- 김진욱,Kim. Jin-Wook
- ㆍ 간행물명
- 대한악안면성형재건외과학회지
- ㆍ 권/호정보
- 2008년|30권 6호|pp.546-553 (8 pages)
- ㆍ 발행정보
- 대한악안면성형재건외과학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Purpose: The purpose of this study was to estimate validity of posterior anterior cephalometric and 3D-CT for orbital canting analysis. Materials and methods: Three trained observers classified two patients group using standardized frontal photographs of facial asymmetry patients. Group A consisted of patients with facial asymmetry and orbital canting(n=19), and group B consisted of patients with only facial asymmetry(n=43). Orbital canting was measured with line of bilateral inferior orbitale. Orbital canting measurement was done with posterior anterior cephalometric and 3D-CT. Each horizontal reference line was established by bilateral GWSO(cephalometric), FZS(3D-CT). Maxillary canting and mandibular deviation angle were also measured and analyzed with orbital canting. Results: The mean orbital canting was $3.03{pm}1.00^{circ}$ in Group A and $1.11{pm}0.76^{circ}$ in Group B in frontal photograph. The mean orbital canting was $1.20{pm}0.74^{circ}$ in group A and $1.22{pm}0.65^{circ}$ in group B by cephalometric analysis(p>0.05). In 3D-CT, orbital canting was almost paralleled with horizontal reference line. The orbital canting, maxillay canting and mandibular deviation between two groups showed no significant differences except madibular deviation in 3D-CT. Conclusion: Common analysis of posterior anterior cephalometric and 3D-CT is not valide method to evaluate orbital canting for facial asymmetry patients with orbital canting.