기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
염산펙소페나딘 120밀리그람 정제의 생물학적동등성시험
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 염산펙소페나딘 120밀리그람 정제의 생물학적동등성시험
  • Bioequivalence Test of Fexofenadine Hydrochloride 120 mg Tablets
저자명
조혜영,강현아,김세미,이용복,Cho. Hea-Young,Kang. Hyun-Ah,Kim. Se-Mi,Lee. Yong-Bok
간행물명
약학회지
권/호정보
2008년|52권 3호|pp.188-194 (7 pages)
발행정보
대한약학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Fexofenadine, ($pm$)-4-1-hydroxy-4-{4-(hydroxydiphenylmethyl)-1-piperidinyl}-butyl-a,a-dimethyl benzeneacetic acid, is a selective histamine $H_1$ receptor antagonist, and is clinically effective in the treatment of seasonal allergic rhinitis and chronic idiopathic urticaria as a first-line therapeutic agent. The purpose of the present study was to evaluate the bioequivalence of two fexofenadine hydrochloride tablets, $Allegra^{(R)}$ (Handok Pharmaceuticals Co., Ltd.) and Alecort (Samchundang Pharmaceutical Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of fexofenadine from the two fexofenadine hydrochloride formulations in vitro was tested using KP VIII Apparatus II method with various dissolution media. Twenty six healthy male subjects, 25.62$pm$3.35 years in age and 70.05$pm$11.71 kg in body weight, were divided into two groups and a randomized 2$ imes$2 cross-over study was employed. After a single tablet containing 120 mg as fexofenadine hydrochloride was orally administered, blood samples were taken at predetermined time intervals and the concentrations of fexofenadine in serum were determined using HPLC with fluorescence detector. The dissolution profiles of two formulations were similar in all tested dissolution media. The harmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated, and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Allegra^{(R)}$, were -1.37, 5.22 and 16.50% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., log 0.83$sim$log 1.08 and log 0.81$sim$log 1.03 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Alecort tablet was bioequivalent to $Allegra^{(R)}$ tablet.