Simultaneous Determination of Triterpenoid Saponins from Pulsatilla koreana using High Performance Liquid Chromatography Coupled with a Charged Aerosol Detector (HPLC-CAD)
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Simultaneous Determination of Triterpenoid Saponins from Pulsatilla koreana using High Performance Liquid Chromatography Coupled with a Charged Aerosol Detector (HPLC-CAD)
저자명
Yeom. Hye-Sun,Suh. Joon-Hyuk,Youm. Jeong-Rok,Han. Sang-Beom
간행물명
Bulletin of the Korean Chemical Society
권/호정보
2010년|31권 5호|pp.1159-1164 (6 pages)
발행정보
대한화학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Several triterpenoid saponins from root of Pulsatilla koreana Nakai (Ranunculaceae) were studied and their biological activities were reported. It is difficult to analyze triterpenoid saponins using HPLC-UV due to the lack of chromophores. So, evaporative light scattering detection (ELSD) is used as a valuable alternative to UV detection. More recently, a charged aerosol detection (CAD) has been developed to improve the sensitivity and reproducibility of ELSD. In this study, we developed and validated a novel method of high performance liquid chromatography coupled with a charged aerosol detector for the simultaneous determination of four triterpenoid saponins: pulsatilloside E, pulsatilla saponin H, anemoside B4 and cussosaponin C. Analytes were separated by the Supelco Ascentis$^{(R)}$ Express C18 column (4.6 mm ${ imes}$ 150 mm, 2.7 ${mu}m$) with gradient elution of methanol and water at a flow rate of 0.8 mL/min at $30^{circ}C$. We examined various factors that could affect the sensitivity of the detectors, including various concentrations of additives, the pH of the mobile phase, and the CAD range. Linear calibration curves were obtained within the concentration ranges of 2 - 200 ${mu}g$/mL for pulsatilloside E, anemoside $B_4$ and cussosaponin C, and 5 - 500 ${mu}g$/mL for pulsatilla saponin H with correlation coefficient ($R^2$) greater than 0.995. The limit of detection (LOD) and quantification (LOQ) were 0.04 - 0.2 and 2 - 5 ${mu}g$/mL, respectively. The validity of the developed HPLC-CAD method was confirmed by satisfactory values of linearity, intra- and inter-day accuracy and precision. This method could be successfully applied to quality evaluation, quality control and monitoring of Pulsatilla koreana.