기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가
저자명
이동훈,홍철표,한봉수,김형진,서재준,김소현,이춘형,이만우,Lee. D.H.,Hong. C.P.,Han. B.S.,Kim. H.J.,Suh. J.J.,Kim. S.H.,Lee. C.H.,Lee. M.W.
간행물명
Journal of biomedical engineering research : the official journal of the Korean Society of Medical & Biological Engineering
권/호정보
2011년|32권 3호|pp.245-250 (6 pages)
발행정보
대한의용생체공학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{ imes}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.