- EGR Cooler 내부 형상에 따른 Fouling이 냉각 성능에 미치는 영향
- ㆍ 저자명
- 남연우,오광철,이천환,이춘범,이원남,Nam. Youn-Woo,Oh. Kwang-Chul,Lee. Chun-Hwan,Lee. Chun-Beom,Lee. Won-Nam
- ㆍ 간행물명
- 한국자동차공학회논문집
- ㆍ 권/호정보
- 2011년|19권 1호|pp.101-108 (8 pages)
- ㆍ 발행정보
- 한국자동차공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Understanding the exhaust gas recirculation (EGR) cooler fouling in diesel engine is important factor in the durability characteristic of a EGR system. We develope a test rig and PM feeder using carbon black to examine the effect of fouling on EGR cooler devices those were consisted of flat and shell & tube type. The EGR cooler fouling process is a complex interaction involving heat exchanger shape, boundary condition, constitutes, chemistry and operating mode. As the soot deposited to EGR cooler, these formed a thin deposit layer that was less heat exchange than the fresh status of tube enclosing the exhaust gas, resulting in lower heat exchange effectiveness in both type coolers. But these deposits caused different results in pressure drop, it is increased in flat type, but decreased in Shell & tube type of EGR cooler. A cause was estimated from a change of the flow structure and a decrease of contact area as the EGR cooler fouling.