- 상수원수의 혼화 및 응집 조건에 따른 DAF pump 장치의 부상분리효율
- ㆍ 저자명
- 안갑환,이창한,Ahn. Kab-Hwan,Lee. Chang-Han
- ㆍ 간행물명
- 한국환경과학회지
- ㆍ 권/호정보
- 2011년|20권 5호|pp.639-645 (7 pages)
- ㆍ 발행정보
- 한국환경과학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This study found that flotation efficiencies for removing algae and micro particles in raw water were optimized on mixing intensity and time of the mixing and flocculation conditions with a continuous DAF system. It is more efficient for mixing intensity at 23.1 $s^{-1}$ and time at 660 s(Gt value : 15246) to float flocculated floc with the raw water in M water treatment plant. Flotation efficiency was more than about 0.9 when operated pressure and A/S ratio were sustained at 5 $kg_f{cdot}cm^{-2}$ and up to 0.056 $mL{cdot}mg^{-1}$. The continuous DAF system made by the study could be continuously operated for 20 days and sustained not exceeding 4 NTU with raw water with low turbidity(13.4~9.8 NTU).