기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Rapid and Simple Method for the Determination of Pregabalin in Human Plasma using Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS): Application to a Bioequivalence Study of Daewoong Pregabalin Capsule To Lyrica? Capsule (Pregabalin 150
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Rapid and Simple Method for the Determination of Pregabalin in Human Plasma using Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS): Application to a Bioequivalence Study of Daewoong Pregabalin Capsule To Lyrica? Capsule (Pregabalin 150
저자명
Jang. Ki-Ho,Seo. Ji-Hyung,Yim. Sung-Vin,Lee. Kyung-Tae
간행물명
Journal of pharmaceutical investigation
권/호정보
2011년|41권 4호|pp.255-262 (8 pages)
발행정보
한국약제학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Method using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the determination of pregabalin in plasma samples. Acquisition was performed by monitoring the transitions: m/z 160.1${ ightarrow}$142.2 for pregabalin and m/z 423.2${ ightarrow}$207.1 for losartan (as an internal standard). After cold acetonitrileinduced protein precipitation of the plasma samples, separation was performed with C18 column by isocratic mobile phase consisted of 10 mM ammonium acetate and acetonitrile (15:85, v/v). Results were linear over the concentration ranged from 0.1 to $10{mu}g$/mL and the correlation coefficients (r) were $geq0.99$. Intra- and inter-day precisions were $leq6.02$ and $leq11.04%$, respectively, and intra- and inter-day accuracies were 96.60-101.09 and 98.10-102.60%, respectively. This validated method was successfully applied to a bioequivalence study of two formulations of pregabalin, Daewoong pregabalin capsule (Daewoong Pharm. Co., Ltd.) and Lyrica$^{(R)}$ capsule (Pfizer Korea Ltd.) in twenty eight healthy Korean volunteers. The subjects received a single oral dose of each formulation (150 mg as pregabalin) in a randomized $2{ imes}2$ crossover study and plasma samples were obtained from each subject at predetermined time intervals. Then, the pharmacokinetic parameters ($AUC_{0-t}$, $C_{max}$ and $T_{max}$) were calculated and statistically analyzed to assess the differences between two formulations. The 90% confidence intervals for the log-transformed data were acceptable range of log 0.8-log 1.25 (e.g., log 1.0048-log 1.0692 for AUC0-t, log 0.9142-log 1.0421 for $C_{max}$). Thus, $AUC_{0-t}$ and $C_{max}$ met the criteria of the Korea Food and Drug Administration (KFDA) for bioequivalence test indicating that Daewoong pregabalin capsule was bioequivalent to Lyrica$^{(R)}$ capsule.