기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Development of HPLC Determination Method for Trace Levels of 1-, 2-Nitropyrenes and 2-Nitrofluoranthene in Airborne Particulates and Its Application to Samples Collected at Noto Peninsula
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Development of HPLC Determination Method for Trace Levels of 1-, 2-Nitropyrenes and 2-Nitrofluoranthene in Airborne Particulates and Its Application to Samples Collected at Noto Peninsula
  • Development of HPLC Determination Method for Trace Levels of 1-, 2-Nitropyrenes and 2-Nitrofluoranthene in Airborne Particulates and Its Application to Samples Collected at Noto Peninsula
저자명
Hayakawa. Kazuichi,Tang. Ning,Sato. Kosuke,Izaki. Akihiko,Tatematsu. Michiya,Hama. Hirotaka,Li. Ying,Kameda. Takayuki,Toriba. Ak
간행물명
Asian journal of atmospheric environment
권/호정보
2011년|5권 3호|pp.146-151 (6 pages)
발행정보
한국대기환경학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

1-Nitropyrene (1-NP), 2-NP and 2-nitrofluoranthene (2-NFR) are useful markers for studying the atmospheric behaviors of polycyclic aromatic hydrocarbons (PAHs) and nitropolycyclic aromatic hydrocarbons (NPAHs). However, present methods for measuring trace levels of these compounds are lesssensitive and laborious. Here we describe several improvements to a previously reported high-performance liquid chromatography-chemiluminescence detection system that allows it to determine trace levels of 1-, 2-NPs and 2-NFR. The proposed system was equipped with a reducer column packed with Pt/Rh instead of zinc whose life-time was limited. The combination of Cosmosil MS-II (monomeric ODS) and AR-II (polymeric ODS) columns was used instead of polymeric ODS columns as the separator column to improve the separation. An ethanol mixture with acetate buffer (pH 5.5) was used in place of an acetonitrile mixture with the same buffer to activate the reducer column. The same ethanol mixture was used as the mobile phase for the clean-up column. The switching time of the column switching valve was optimized to concentrate the amino-derivatives of above NPAHs quantitatively on the concentrator column. The concentrations of bis(2,4,6-trichlorophenly) oxalate and hydrogen peroxide in the chemiluminescence reagent solution were optimized to 0.4 mM and 30 mM, respectively, to increase the sensitivity. Under the above conditions, the detection limits (S/N=3) of 1-, 2-NPs and 2-NFR were 1 fmol (0.25 pg), 10 fmol (2.5 pg) and 4 fmol (1 pg), respectively. The proposed system was effectively used to determine trace levels of 1-, 2-NPs and 2-NFR in airborne particulates collected at Noto Peninsula. The atmospheric concentrations of 1-, 2-NPs and 2-NFR were not more than sub pg $m^{-3}$ levels. They were higher in winter (January) than in summer (July). In both seasons, the concentrations were in decreasing order, [2-NFR]>[1-NP]>[2-NP].