- 7공 프로브의 원추각이 유동 측정 정확도에 미치는 영향에 대한 연구
- ㆍ 저자명
- 이용진,박정신,노영철,전창수,곽재수,Lee. Yong-Jin,Park. Jung-Shin,Nho. Young-Cheol,Jeon. Chang-Soo,Kwak. Jae-Su
- ㆍ 간행물명
- 유체기계저널
- ㆍ 권/호정보
- 2011년|14권 5호|pp.5-11 (7 pages)
- ㆍ 발행정보
- 유체기계공업학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
In this study, the effect of cone angle of seven-hole probe on the accuracy of measured flow angle and velocity has been investigated. The seven-hole probe consisted of seven 1mm OD stainless inner tubes and one 3mm ID stainless tube. Six cone angles of $45^{circ}$, $60^{circ}$, $75^{circ}$, $90^{circ}$, $105^{circ}$ and $120^{circ}$ were tested. Calibrations of the seven-hole probes were conducted within ${pm}60^{circ}$ range with the interval of $5^{circ}$. Analysis results show that the effect on the cone angle was not significant on the accuracy of the measured flow angle, pressure, and velocity. However, the data reduction method had more effect on the measurement accuracy.