- 소형 자연순환 수직형 증발기 해석 및 성능실험
- ㆍ 저자명
- 차상진,김내현,유진상,Cha. Sang-Jin,Kim. Nae-Hyun,Ryu. Jin-Sang
- ㆍ 간행물명
- 설비공학논문집
- ㆍ 권/호정보
- 2011년|23권 9호|pp.595-603 (9 pages)
- ㆍ 발행정보
- 대한설비공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
In this study, an effort has been made to analyze the subcooled boiling heat transfer in a natural circulation vertical evaporator. To verify the analysis, a small-scale model was made and tested. The friction correlation by Ueda, void fraction and quality correlation by Saha and Zuber along with the superposition heat transfer model by Rohsenow yielded a satisfactory agreement with the model test data. The analysis was extended to simulate a 1 ton/day concentration system. Comparison with the test results of 1 ton/day prototype revealed that the data were overpredicted by 13%. The capacity of the prototype was 1.2 ton/day with COP of 5.77.