- 수소 충전소에 대한 정량적 안전성 평가
- ㆍ 저자명
- 성대현,이광원,김태훈,오동석,오영달,서두현,김영규,김은정,Seong. D.H.,Rhie. K.W.,Kim. T.H.,Oh. D.S.,Oh. Y.D.,Seo. D.H.,Kim. Y.G.,Kim. E.J.
- ㆍ 간행물명
- 한국안전학회지
- ㆍ 권/호정보
- 2012년|27권 3호|pp.111-116 (6 pages)
- ㆍ 발행정보
- 한국안전학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This study is about the quantitative safety assessment of hydrogen station in Korea operating with on-site type. This was written by background information that before qualitative safety assessment to write. For the qualitative safety assessment method, the study used FMEA(failure mode & effect analysis) and HAZOP(hazard & operability), and adopted the FTA(fault tree analysis) as the quantitative safety assessment method. To write the FTA, we wrote FT by Top event that hydrogen leakage can be called most serious accident of hydrogen station. Each base event collect reliability data by reliability data handbook, THERP-HRA and estimation of the engineering. Assessment looked at the high frequency and the possible risk through Gate, Importance, m.cutsets analysis.