- 풍력발전기 너셀에 장착된 풍속계를 이용한 출력성능 평가
- ㆍ 저자명
- 김수상,박세광,Kim. Soo-Sang,Park. Se-Kwang
- ㆍ 간행물명
- Journal of sensor science and technology
- ㆍ 권/호정보
- 2012년|21권 4호|pp.303-310 (8 pages)
- ㆍ 발행정보
- 한국센서학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
We carried out the power performance evaluation for 1.5 MW${ imes}$2 by using anemometer installed on WTGS(Wind Turbine Generator System) in the wind farm at Shi-hwa bang-a-mu-ri. In this paper, we compared and analyzed the performance of guaranteed output and measured output of WTGS which includes output curve, output coefficient, AEP(Annual Energy Product) and availability, etc.. The power performance of WTGS was optimized in the low wind speed sections(3 m/s ~ 10 m/s) and the measured output was more produced by AEP 109 % and availability 112 % than the guaranteed output. In addition, we could also cut the high cost of testing WTGS performance by using anemometer as a substitute for weather mast.