기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Rapid Determination of Ginkgolic Acids in Ginkgo biloba Leaf Using Online Column Switching High-Performance Liquid Chromatography-Diode Array Detection and Confirmation by Liquid Chromatography-tandem Mass Spectrometry
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Rapid Determination of Ginkgolic Acids in Ginkgo biloba Leaf Using Online Column Switching High-Performance Liquid Chromatography-Diode Array Detection and Confirmation by Liquid Chromatography-tandem Mass Spectrometry
  • Rapid Determination of Ginkgolic Acids in Ginkgo biloba Leaf Using Online Column Switching High-Performance Liquid Chromatography-Diode Array Detection and Confirmation by Liquid Chromatography-tandem Mass Spectrometry
저자명
Lee. Hyounyoung,Lim. Heungyoul,Yang. Juhong,Hong. Jongki
간행물명
Bulletin of the Korean Chemical Society
권/호정보
2013년|34권 12호|pp.3629-3634 (6 pages)
발행정보
대한화학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

In this study, an improved method for the quantitative analysis of ginkgolic acids (GAs) in Ginkgo biloba leaf extract was developed. The samples were extracted with a mixture of chloroform and 50 % ethanol, after which the chloroform extract was dried and reconstituted in methanol. GAs with 13:0, 15:1, and 17:1 in the extract were successfully separated within 40 min and determined with high throughput performance using an online column-switching HPLC method using an SP column C8 SG80 ($4.6{ imes}150mm$, $5{mu}m$) and a Cadenza 5CD C18 column ($4.6{ imes}150mm$, $3{mu}m$). The developed HPLC method was validated for Ginkgo biloba leaf extract. The validation parameters were specificity, linearity, precision, accuracy, and limits of detection and quantitation (LODs and LOQs, respectively). It was found that all of the calibration curves showed good linearity ($r^2$ > 0.9993) within the tested ranges. The LODs and LOQs were all lower than $0.04{mu}g/mL$. The established method was found to be simple, rapid, and high throughput for the quantitative analysis of GAs in ten commercial Ginkgo biloba leaf extract and dietary supplements. The samples were also analyzed in LC-electrospray ionization (ESI) tandem mass spectrometry (MS/MS) - multiple-ion reaction monitoring (MRM) mode to confirm the identification results that were obtained by the column switching HPLC-DAD method. The developed method is considered to be suitable for the routine quality control and safety assurance of Ginkgo biloba leaf extract.