- 다지점 진동대를 이용한 원자력발전소 배관계통의 내진성능실험
- ㆍ 저자명
- 정진환,계만수,서영득,최형석,김민규,Cheung. Jin-Hwan,Gae. Man-Soo,Seo. Young-Deuk,Choi. Hyoung-Suk,Kim. Min-Kyu
- ㆍ 간행물명
- 한국지진공학회논문집
- ㆍ 권/호정보
- 2013년|17권 1호|pp.21-31 (11 pages)
- ㆍ 발행정보
- 한국지진공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
In this study, dynamic characteristics and seismic capacity of the nuclear power plant piping system are evaluated by model test results using multi-platform shake table. The model is 21.2 m long and consists of straight pipes, elbows, and reducers. The stainless steel pipe diameters are 60.3 mm (2 in.) and 88.9 mm (3 in.) and the system was assembled in accordance with ASME code criteria. The dynamic characteristics such as natural frequency, damping and acceleration responses of the piping system were estimated using the measured acceleration, displacement and strain data. The natural frequencies of the specimen were not changed significantly before and after the testing and the failure and leakage of the piping system was not observed until the final excitation. The damping ratio was estimated in the range of 3.13 ~ 4.98 % and it is found that the allowable stress(345 MPa) according to ASME criteria is 2.5 times larger than the measured maximum stress (138 MPa) of the piping system even under the maximum excitation level of this test.