- 스펙트럼 적합 입력지반운동에 의한 면진구조의 응답 특성
- ㆍ 저자명
- 김정한,김민규,최인길,Kim. Jung Han,Kim. Min Kyu,Choi. In-Kil
- ㆍ 간행물명
- 한국지진공학회논문집
- ㆍ 권/호정보
- 2013년|17권 2호|pp.89-95 (7 pages)
- ㆍ 발행정보
- 한국지진공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Structures in a nuclear power system are designed to be elastic even under an earthquake excitation. However a structural component such as an isolator shows inelastic behavior inherently. For the seismic assessment of nonlinear structures, response history analysis should be performed. In this study, the response of base isolation system was analyzed by response history analysis for the seismic performance assessment. Firstly, several seismic assessment criteria for a nuclear power plant structure were reviewed for the nonlinear response history analysis. Based on these criteria, the spectrum matched ground motion generation method modifying a seed earthquake ground motion time history was adjusted. Using these spectrum matched accelerograms, the distribution of displacement responses of the simplified base isolation system was evaluated. The resulting seismic responses excited by the modified ground motion time histories and the synthesized time history generated by stochastic approach were compared. And the response analysis of the base isolation system considering the different intensities in each orthogonal direction was performed.