- 코발트-크롬 합금으로 제작된 금속-도재관의 적합도 평가
- ㆍ 저자명
- 김재홍,김원수,김기백,Kim. Jae-Hong,Kim. Won-Soo,Kim. Ki-Baek
- ㆍ 간행물명
- JKSDH : Journal of Korean Society of Dental Hygiene
- ㆍ 권/호정보
- 2013년|13권 2호|pp.361-368 (8 pages)
- ㆍ 발행정보
- 한국치위생학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Objectives : The purpose of this in vitro study was to evaluate the effect of firing cycles on the marginal and internal fit of metal ceramic crown. Methods : Ten same cases of stone models (abutment teeth 11) were manufactured. Ten cobalt-chrome cores were made per each models and the marginal and internal fit was evaluated through a silicone replica technique. The marginal and internal fit of specimens was measured twice. The first measurement was done after manufacturing cobalt-chrome alloy core and the second measurement was done after porcelain firing. T-test of paired sample for statistical analysis was executed with SPSS 12.0K for Windows (${alpha}$=0.05). Results : Mean(SD) marginal and internal fit were 77.1(23.3) ${mu}m$ for the cobalt-chrome alloy core group and 84.4(21.9) ${mu}m$ for the metal-ceramic crown group. They were statistically significant differences between groups for marginal and internal fit (p<.05). Conclusions : All metal ceramic crowns showed marginal and internal fit ranged within the current clinical recommendations.