기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions
  • Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions
저자명
Nikneshan. Sima,Sharafi. Mohamad,Emadi. Naghmeh
간행물명
Imaging science in dentistry
권/호정보
2013년|43권 3호|pp.191-196 (6 pages)
발행정보
대한구강악안면방사선학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Purpose: This study assessed the accuracy of linear and angular measurements on panoramic radiographs taken at different positions in vitro. Materials and Methods: Two acrylic models were fabricated from a cast with normal occlusion. Straight and $75^{circ}$ mesially and lingually angulated pins were placed, and standardized panoramic radiographs were taken at standard position, at an $8^{circ}$ downward tilt of the occlusal plane compared to the standard position, at an $8^{circ}$ upward tilt of the anterior occlusal plane, and at a $10^{circ}$ downward tilt of the right and left sides of the model. On the radiographs, the length of the pins above (crown) and below (root) the occlusal plane, total pin length, crown-to-root ratio, and angulation of pins relative to the occlusal plane were calculated. The data were subjected to repeated measures ANOVA and LSD multiple comparisons tests. Results: Significant differences were noted between the radiographic measurements and true values in different positions on both models with linear (P<0.001) and those with angulated pins (P<0.005). No statistically significant differences were observed between the angular measurements and baselines of the natural head posture at different positions for the linear and angulated pins. Conclusion: Angular measurements on panoramic radiographs were sufficiently accurate and changes in the position of the occlusal plane equal to or less than $10^{circ}$ had no significant effect on them. Some variations could exist in the pin positioning (head positioning), and they were tolerable while taking panoramic radiographs. Linear measurements showed the least errors in the standard position and $8^{circ}$ upward tilt of the anterior part of the occlusal plane compared to other positions.