- 수치해석을 이용한 평균 양방향 유동 튜브 유량계의 파울링 환경 적용성 연구
- ㆍ 저자명
- 박종필,정지환,강경호,백원필,윤병조,Park. JongPil,Jeong. JiHwan,Kang. KyongHo,Baek. WonPil,Yun. ByongJo
- ㆍ 간행물명
- 한국유체기계학회 논문집
- ㆍ 권/호정보
- 2013년|16권 4호|pp.35-43 (9 pages)
- ㆍ 발행정보
- 한국유체기계학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Most of the nuclear power plants(NPPs) adopts pressure difference type flow meters such as venturi and orifice meters for the measurement of feedwater flow rates to calculate reactor thermal power. However, corrosion products in the feedwater deposits on the flow meter by fouling as operating time goes. These effects lead to severe errors in the flow indication and then determination of reactor thermal power. The averaging BDFT, which has developed by Yun et al., has a potentiality to minimize this problem thanks to its inherent measurement principle. Therefore, it is expected that the averaging BDFT can replace the venturi meter for the feedwater pipe of steam generator of NPPs. The present work compares the amplification factor, K, based on CFD calculation against the K obtained from experiments in order to confirm whether a commercial CFD code can be applicable to the evaluation of characteristic for the averaging BDFT. In addition to this, the simulations to take into account of fouling effect are also carried out by rough wall option. The results show that the averaging BDFT is a promising flow meter for the accurate measurement of flow rates in the fouling condition of the NPPs.