- 산업단지 폐수발생량 원단위 산정 비교연구
- ㆍ 저자명
- 김준엽,최경식,Kim. Joon-Yup,Choi. Kyoung-Sik
- ㆍ 간행물명
- 上下水道學會誌
- ㆍ 권/호정보
- 2014년|28권 3호|pp.339-344 (6 pages)
- ㆍ 발행정보
- 대한상하수도학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The predictive capacity of wastewater treatment facility in the industrial park was estimated by the traditional method and on-the-spot survey such as certification of wastewater report and the invoices of water supply and ground water supply. The ratios of a converted wastewater to supplied industrial water between traditional method and on-the-spot survey in the estimation methods were different. By using traditional method, the business type of clothes, accessary and fur production had 77.18 % of waste ratio of wastewater and $10.72m^3/day{cdot}1000m^2$ unit mass of wastewater as the highest among 9 business types. With the respect to the on-the-spot survey, food manufacturing business type had 75 % of waste ratio of wastewater and $8.35m^3/day{cdot}1000m^2$ unit mass of wastewater as the highest values. The amount of wastewater from on-the-spot survey method was 541 $m^3/day$ less than one from traditional method.