기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Diagnostic Values of Serum Levels of Pepsinogens and Gastrin-17 for Screening Gastritis and Gastric Cancer in a High Risk Area in Northern Iran
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Diagnostic Values of Serum Levels of Pepsinogens and Gastrin-17 for Screening Gastritis and Gastric Cancer in a High Risk Area in Northern Iran
  • Diagnostic Values of Serum Levels of Pepsinogens and Gastrin-17 for Screening Gastritis and Gastric Cancer in a High Risk Area in Northern Iran
저자명
Nejadi-Kelarijani. Fatemeh,Roshandel. Gholamreza,Semnani. Shahryar,Ahmadi. Ali,Faghani. Behzad,Besharat. Sima,Akhavan-Tabib. Ate
간행물명
Asian Pacific journal of cancer prevention : APJCP
권/호정보
2014년|15권 17호|pp.7433-7436 (4 pages)
발행정보
아시아태평양암예방학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Background: Gastric cancer (GC) is the second cause of cancer related death in the world. It may develop by progression from its precancerous condition, called gastric atrophy (GA) due to gastritis. The aim of this study was to evaluate the accuracy of serum levels of pepsinogens (Pg) and gastrin-17 (G17) as non-invasive methods to discriminate GA or GC (GA/GC) patients. Materials and Methods: Subjects referred to gastrointestinal clinics of Golestan province of Iran during 2010 and 2011 were invited to participate. Serum levels of PgI, PgII and G17 were measured using a GastroPanel kit. Based on the pathological examination of endoscopic biopsy samples, subjects were classified into four groups: normal, non-atrophic gastritis, GA, and GC. Receiver operating curve (ROC) analysis was used to determine cut-off values. Indices of validity were calculated for serum markers. Results: Study groups were normal individuals (n=74), non-atrophic gastritis (n=90), GA (n=31) and GC patients (n=30). The best cut-off points for PgI, PgI/II ratio, G17 and HP were $80{mu}g/L$, 10, 6 pmol/L, and 20 EIU, respectively. PgI could differentiate GA/GC with high accuracy (AUC=0.83; 95%CI: 0.76-0.89). The accuracy of a combination of PgI and PgI/II ratio for detecting GA/GC was also relatively high (AUC=0.78; 95%CI: 0.70-0.86). Conclusions: Our findings suggested PgI alone as well as a combination of PgI and PgI/II ratio are valid markers to differentiate GA/GC. Therefore, Pgs may be considered in conducting GC screening programs in high-risk areas.