기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
신장과 체중을 이용한 남자의 신체 용적 간접 측정
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 신장과 체중을 이용한 남자의 신체 용적 간접 측정
  • Prediction of Human Body Volume from Height and Weight
저자명
김기용(Kim, Key-Yong)
간행물명
대한생리학회지
권/호정보
1970년|4권 2호(통권8호)|pp.37-44 (8 pages)
발행정보
대한생리학회|한국
파일정보
정기간행물|KOR|
PDF텍스트(0.28MB)
주제분야
의약학
서지반출

영문초록

Human body volumes were calculated from the measurments of body height and body weight. Equations Suited to express the relations of height, weight, and surface area to show the body volume were derived from the body volume measurements by means of underwater. weighing method. Underwater body weights were corrected for the residual volume of long obtained by the Rahn s three breath method. Underwater weighing was performed on 173 male subjects aged between 13 and 51 years. Subjects were divided into 4 age groups, namely, 13-16 years group of 47 subjects, 16-19 years group of 46 subjects, adult group aged between 22 and 38 years comprising 45 subjects, and middle-aged group (40-51 years) of 35 subjects. The group division was made on .the basis of physical growth and development. The following results were obtained. 1. Body height (H, cm), body weight (W, kg), body surface area S, m2), and body volume (V, liter.) interrelated closely. V/S showed a high correlation with W/H and the coefficient of correlation was r=0.97 irrespective of age group differences of the subjects. The coefficients of correlation between V/S and W/H in the total mate subjects as a single group was r=1.983. Subsequently the following regression equation was obtained. V = S X (54.84 W/H + 14.08) The agreement of body volume values obtained by the calculation and underwater weighing in the total subject group was better than that of the separate age group division. 2. The calculated values of body volume were: 40.4 l (euiqvalent to the body density value of 1.0562 kg/1) in 13-16 years group; 52.0 l (equivalent to density value of 1.0723 kg/l) in 16-19 years group; 55.3 l (equivalent to density value of 1.0570 kg/l) In the adult group; and 54. 0 l (equivalent to density value of 1.074 kg/l) in the middle-age group. The mean deviation of calculated from the measured volume value ranged between ±0.55 and ±0.81 liters. 3. The correlation between V/S and mean skinfold thickness of 4 sites (arm, back, iliac and chest) was high, namely, the coefficient of correlation was r=0.656. The coefficients of correlation between V./S and the RÖhrer index ranged between r=0.668 and r=0.810 affected by the difference in group age of the subject. The body volume (V) alone correlated poorly than V/S with mean skinfold thickness (r=0.606) and the RÖhrer index (r ranged between 0.274 and 0.588).

구매하기 (3,000)