기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Treadmill 최대 운동시 Impedance 심장기록법의 개선에 의한 마라톤 선수의 심박출량과 산소소비량과의 관계
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Treadmill 최대 운동시 Impedance 심장기록법의 개선에 의한 마라톤 선수의 심박출량과 산소소비량과의 관계
  • Relationship between Oxygen Uptake and Cardiac Output on Maximal Treadmill Exercise in Marathoners by Improved Impedance Cardiography
저자명
강두희(Kang, Doo-Hee),황수관(Hwang, Soo-Kwan),연동수(Yeon, Dong-Soo),유선희(Yuh, Seon-Hee),김덕원(Kim, Deok-Won)
간행물명
대한생리학회지
권/호정보
1990년|24권 2호(통권46호)|pp.249-260 (12 pages)
발행정보
대한생리학회|한국
파일정보
정기간행물|KOR|
PDF텍스트(0.37MB)
주제분야
의약학
서지반출

영문초록

Maximal cardiac output and oxygen uptake (VO2max) were measured during treadmill exercise for seven top-class marathoners and nine non-athletes using impedance cardiograph developed by one of the authors (DW Kim). Results of this study are summarized as belows. 1) New shoes with sponge and silicon rubber attached to the soles were developed to reduce motion artifact during treadmill exercise. Ensemble everaging techneque with the developed shoes was also used to improve the measurement of stroke volume using impedance cardiography. 2) Maximal cardiac output of the athletes, 14.98 L/min, was significantly higher than that of the non-athletes, 13.46 L/min. As maximal heart rate of the marathoners is lower than that of non-athletes, stroke volume of the former is significantly larger than that of the latter. 3) (VO2max) of the marathoners, 59.38 ml/kg/min, was higher than that of the non-athletes, 40.22 ml/kg/min. At the anaerobic threshold. (VO2max) of the former was 62.3% of (VO2max) and this was significantly higher than that of the non-athletes, 57.2%, This results indicates that the marathoners have higher aerobic capacity than the non-athletes. 4) The marathoners showed larger VO2 than the non-athletes at the same cardiac output, indicating that a-v O2 of the former is higher than that of the latter. 5) Maximal systolic pressure of the marathoners was higher than that of the non-athletes, and so was maximal rate-pressure products. These results indicate that heart oxygen consumption rate (hVO2) of the marathoner is higher than that of the non-athletes is mainly due to higher stroke volume. And higher oxygen consumption of the marathoners is due to higher stroke volume. And higher oxygen consumption of the marathoners is due to their larger a-v O2. The marathoners show both higher threshold and (VO2max). Especially, measurement of cardiac output during treadmill exercise by improved impedance cardiography is expected to contribute in study of cardiac function of athletes.

구매하기 (4,100)