기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Assessment of DP Threshold and its Test–Retest Reliability in Normal Hearing Individuals
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Assessment of DP Threshold and its Test–Retest Reliability in Normal Hearing Individuals
  • Assessment of DP Threshold and its Test–Retest Reliability in Normal Hearing Individuals
저자명
Anuj Kumar Neupane, Kalpesh Bheda Gunjan Mehta
간행물명
Clinical Archives of Communication DisordersSCOPUS
권/호정보
2023년|8권 3호(통권22호)|pp.211-216 (6 pages)
발행정보
한국언어재활사협회|한국
파일정보
정기간행물|KOR|
PDF텍스트(0.34MB)
주제분야
의약학
서지반출

국문초록

Purpose: Distortion Product (DP) threshold test has been recently introduced as a clinical tool that provides frequency specific quantitative information on hearing sensitivity in dB HL. However, due to the dearth of literature in determining its degree of reliability, the extent of confidence in the test results has not been estimated. Therefore, the present study aimed at establishing the normative of DP threshold values across test frequencies in normal hearing individuals and check for its test-retest reliability. Methods: Purposive sampling was utilized in the study wherein fifty normal hearing individuals in the age range of 18 to 30 years (x̅=24, σ=2.1) were considered. DP threshold test was carried out across test frequencies from 1 kHz to 8 kHz in measurement window of 50 dB HL and was re-examined after 15 days. Results: The range of DP threshold level was -5 to 20 dB HL in right ear and -5 to 25 dB HL in left ear across the test frequencies. It was found to have the mean difference ranging -0.02 to 1.06 dB HL across test frequencies between the two sessions. Non-parametric Wilcoxon Signed Ranks test was performed to assess test-retest reliability which revealed no statistically significant difference for both ears (p>0.05). Conclusions: Hence, the current study presents normative of DP threshold test along with variance, beyond which the fluctuations in outer hair cell functioning can be expected to have occurred. Moreover, it is found to have good test retest reliability between the two sessions suggesting good potentiality of the test in assessing outer hair cells functioning.

영문초록

Purpose: Distortion Product (DP) threshold test has been recently introduced as a clinical tool that provides frequency specific quantitative information on hearing sensitivity in dB HL. However, due to the dearth of literature in determining its degree of reliability, the extent of confidence in the test results has not been estimated. Therefore, the present study aimed at establishing the normative of DP threshold values across test frequencies in normal hearing individuals and check for its test-retest reliability. Methods: Purposive sampling was utilized in the study wherein fifty normal hearing individuals in the age range of 18 to 30 years (x̅=24, σ=2.1) were considered. DP threshold test was carried out across test frequencies from 1 kHz to 8 kHz in measurement window of 50 dB HL and was re-examined after 15 days. Results: The range of DP threshold level was -5 to 20 dB HL in right ear and -5 to 25 dB HL in left ear across the test frequencies. It was found to have the mean difference ranging -0.02 to 1.06 dB HL across test frequencies between the two sessions. Non-parametric Wilcoxon Signed Ranks test was performed to assess test-retest reliability which revealed no statistically significant difference for both ears (p>0.05). Conclusions: Hence, the current study presents normative of DP threshold test along with variance, beyond which the fluctuations in outer hair cell functioning can be expected to have occurred. Moreover, it is found to have good test retest reliability between the two sessions suggesting good potentiality of the test in assessing outer hair cells functioning.

목차

INTRODUCTION
METHODS
RESULTS
DISCUSSION
REFERENCES

구매하기 (3,000)