- 스터링헝 오리피스 맥동관 냉동기의 성능특성에 관한 연구
- ㆍ 저자명
- 홍용주,박성제,김효봉,김양훈,최영돈
- ㆍ 간행물명
- 한국초전도·저온공학회논문지
- ㆍ 권/호정보
- 2002년|4권 2호|pp.63-67 (5 pages)
- ㆍ 발행정보
- 한국초전도저온공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
In this study, the performance of the Stirling type orifice Pulse tube refrigerator (OPTR) with a linear compressor was investigated by experiment. The dynamic pressures at three points and a temperature at the cold heat exchanger are measured to explore the dependency of the orifice on the performance of the OPTR. The experimental results show that the opening of the orifice has significant effects on the no load temperature and cool down characteristics. The Pressure amplitude in Pulse tube decrease as the opening of the orifice increase, but the mass flow rate through the orifice and the electric input Power to the compressor increase. The results show that the operating frequency and charging Pressure does not affect on the no load temperature. The pressure amplitude in pulse tube decrease as the operating frequency increase or the charging Pressure decreased.