- 적외선 센서 냉각용 극저온 용기의 과도 냉각 특성에 관한 수치해석
- ㆍ 저자명
- 이정훈,김호영,강병하
- ㆍ 간행물명
- 한국초전도·저온공학회논문지
- ㆍ 권/호정보
- 2002년|4권 2호|pp.68-72 (5 pages)
- ㆍ 발행정보
- 한국초전도저온공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This work investigates the transient cooling characteristics of an Infrared (IR) detector cryochamber, which has a critical effect on the cooling load. The current thermal modeling considers the conduction heat transfer through a cold well. the gaseous conduction due to outgassing. and the radiation heat transfer. The transient cooling Performance. i.e. the penetration depth and cooling load, is determined using a finite difference method. It is found that the penetration depth increases as the bore conductivity increases. Gaseous conduction and radiation hardly affect the penetration depth. The transient cooling load increases as the bore conductivity increases. The effects of gaseous conduction and radiation on transient heat transfer are weak at initial stages of cooling. However, their effects become significant as the cooling Process Proceeds.