- 고온 원관형 히트파이프의 열전달 특성에 관한 실험 연구
- ㆍ 저자명
- 박수용,부준홍
- ㆍ 간행물명
- 설비공학논문집
- ㆍ 권/호정보
- 2004년|16권 1호|pp.70-76 (7 pages)
- ㆍ 발행정보
- 대한설비공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
High-temperature cylindrical sodium/stainless-steel heat pipes were manufactured and tested for transient as well as steady states. Total length of the heat pipe was 1 m and the diameter was 25.4 mm. Screen meshes of 3 different sizes were used to estimate the effect of mesh size on the thermal performance of the heat pipe. The minimum thermal resistance achieved was as low as 0.02$^{circ}C$/W for the maximum thormal load of 2 ㎾. The average heat transfer coefficient in the evaporator was about 2,000 ㎾/$m^2$K and those in the condenser region were up to 5 times higher.